<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-11 02-20-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 63 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 68 kHz 15143 15,4329
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,12 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 76 kHz: 15,4329 Acquired: 2025/03/11 2.19.17 Total samples: 15143 Equivalent time: 0:12:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,9 dBr MIN: 4,3 dBr AVE: 5,12 dBr % above 12,2 dBr: 0,0 Last value: 4,9 dBr (2025/03/11 2.19.17) 02.06 02.08 02.10 02.12 02.14 02.16 02.18 0 2 4 6 Pm [dBr]